F22 Boiler Fault and F75 Codes: What You Can Reset Yourself

October 6, 2026

Key takeaways

An F22 or F75 on your Vaillant boiler means it has locked out and stopped working. Both codes look the same on the display (a flashing error, no heating, no hot water) but they have different causes, different fixes, and a different answer to the question of whether you need an engineer.

F22 is usually a pressure problem you can resolve yourself. F75 points to the pump or the pressure sensor and, unless low pressure is behind it, needs a Gas Safe registered engineer to diagnose and repair, so it often leads to a boiler repair rather than a simple reset.

F22 vs F75 at a glance

If you are not sure which code applies to you, this table covers the key differences before you work through each one in detail.

F22F75
What it meansSystem pressure too lowPump or pressure sensor fault
Can you fix it yourself?Often, with the filling loopRarely: pressure check and reset only
Common causePressure loss, slow leakLow pressure, air, faulty sensor or pump
Reset resolves it?Yes, if pressure holdsSometimes: monitor for 24 hours
Engineer needed?If pressure drops againIf it returns after a top-up and reset
Target repairSystem leak, expansion vesselSensor replacement, pump replacement

What is the F22 fault code on a Vaillant boiler?

F22 is Vaillant's fault code for low water pressure. It appears when the system pressure drops below approximately 0.5 bar, at which point the boiler locks out to prevent it from running without adequate water circulation. Vaillant names low pressure as one of the most common reasons behind boiler problems.

The three most common causes are natural pressure loss over time, a slow leak at a radiator valve or pipe joint, and air released when bleeding radiators. In the last case, a slight pressure drop after bleeding is normal and expected. If F22 appears repeatedly after repressurising, water is escaping somewhere in the system and needs finding before the problem escalates.

F22: what you can do vs when you need an engineer

Many F22 faults resolve with a pressure top-up and a reset. The table below separates what is safe to do yourself from the signs that the fault needs professional attention.

What you can do yourselfWhen you need an engineer
Check the pressure gaugePressure drops again soon after topping up
Repressurise using the filling loop to between 1 and 1.5 barVisible damp, rust, or limescale around the boiler or pipework
Press the reset button to restart the boilerRelief valve dripping or discharging water outside
Monitor pressure for 24 hours after topping upF22 returns repeatedly over days or weeks

Check the pressure gauge on the front of the boiler. If it reads below 1 bar, repressurise using the filling loop, press the reset button, and monitor for 24 hours. If the pressure holds, the fault is resolved. If the gauge already reads above 1 bar and F22 is still showing, do not add water: that points to a fault such as the pressure sensor or its wiring, which is a job for an engineer.

If it drops again soon after, stop topping up. The system has a fault (a leak, a faulty pressure relief valve, or a failed expansion vessel) that will not resolve itself. Each top-up only masks the problem. At that point, boiler repair by a Gas Safe registered engineer is the right next step.

What causes an F22 fault?

F22 usually comes down to one of three things. Identifying which applies to your system determines whether a top-up resolves it or whether something needs investigating.

Low system pressure

The most common cause. Pressure drops gradually over time in any sealed central heating system. Bleeding radiators, small leaks, or natural pressure loss over months can bring the system below the threshold the boiler needs to operate.

A slow leak in the system

If F22 appears repeatedly after repressurising, water is escaping somewhere. Leaks at radiator valves, pipe joints, or internal boiler components cause the pressure to drop back down within hours or days of being topped up.

A recently bled radiator system

Releasing air from radiators also releases a small amount of water, which lowers pressure. An F22 appearing shortly after bleeding is normal and expected. Check and repressurise after bleeding any radiators.

What is the F75 fault code on a Vaillant boiler?

F75 is Vaillant's fault code for a pressure sensor or pump fault. It appears when the boiler's pump starts but the pressure sensor does not detect the expected change in water pressure. The boiler interprets this as either the pump not running correctly or the pressure sensor failing to register its output.

Unlike F22, F75 is not mainly a pressure problem, although low system pressure is one of the causes Vaillant names, so check the gauge before anything else.

What causes an F75 fault?

Apart from low pressure, F75 has four common causes, all of which involve the pump failing to move water correctly or the sensor failing to confirm that it has. None of them is resolved by topping up the system.

A faulty pressure sensor

If the sensor is defective, stuck, or fouled by sludge, it cannot register the pressure change accurately and triggers F75 even when the pump is working correctly.

A faulty or seized pump

If the pump has seized, is running too slowly, or has failed internally, it cannot generate the pressure change the sensor is looking for. The boiler detects no movement in the system and locks out.

Air in the pump

After a system has been drained and refilled, air trapped in the pump prevents it from circulating water correctly. The pump spins but moves no water, and the pressure sensor registers no change.

System sludge blocking the pump

In older systems, sludge from corroding pipes and radiators can build up and restrict the pump. It runs but cannot generate adequate flow, which can trigger F75 alongside wider circulation problems.

F75: what you can do vs when you need an engineer

F75 has far less user scope than F22. A pressure check and a reset are the only safe interventions. Everything beyond that requires a Gas Safe registered engineer with the right diagnostic equipment.

What you can do yourselfWhen you need an engineer
Check the pressure gauge; repressurise if below 1 barF75 returns after a reset
Press the reset button and monitor for 24 hoursBoiler locks out immediately on restart
Note any unusual pump noise before callingPump making unusual noise or not running
Check when the system was last serviced or flushedSystem not flushed in several years

Check the pressure gauge first, as Vaillant lists low system pressure as one cause of F75. If it reads below 1 bar, repressurise to between 1 and 1.5 bar and attempt a reset. If F75 clears and does not return, low pressure was a contributing factor. If it returns immediately, the fault is most likely in the pump or sensor.

If the reset does not clear the fault or the code returns within a short period, a Gas Safe engineer needs to diagnose whether the fault is the pressure sensor, the pump, or system sludge.

A pressure sensor on a Vaillant ecoTEC is an inexpensive part. A pump replacement costs more. A system powerflush addresses the root cause rather than just the failed component, and is worth considering on any older system where sludge is a likely contributor.

Beyond a pressure check and reset, F75 is not a DIY repair. The pump and pressure sensor sit inside the boiler casing, and opening that casing or repairing any part of a gas boiler, not just its gas supply, is a job for a Gas Safe registered engineer.

Boiler fault codes and landlord obligations

For landlords with residential properties, boiler maintenance is a legal obligation. The Gas Safety (Installation and Use) Regulations 1998 require annual gas safety checks by a Gas Safe registered engineer. A boiler displaying recurring fault codes that has not been properly investigated and repaired is a compliance issue as well as a practical one.

Tenants who report a boiler fault are reporting a loss of heating or hot water, which falls under the landlord's repair obligations. A boiler showing F75 that is left unrepaired, particularly in winter, carries both legal and operational consequences.

For commercial properties and portfolios, recurring boiler faults across multiple sites are most effectively managed through a planned maintenance programme that includes annual servicing and pressure monitoring.

Final thoughts

F22 is a fault many Vaillant boiler owners can resolve themselves: check the pressure, repressurise, reset. If the pressure holds, the job is done. If it drops again, there is a fault in the system that needs professional investigation.

F75 is a different problem. A reset is worth trying, but if the code returns, the boiler needs an engineer. The pump or pressure sensor has most likely failed, and neither is a DIY repair.

Still showing F22 or F75? Get it diagnosed

If repressurising has not cleared the F22, or F75 keeps coming back, the fault needs a Gas Safe engineer on site. FS Group's heating engineers cover London and the South East.

5

Frequently asked questions

What does the f22 fault code mean on a Vaillant boiler?

F22 means the system water pressure has dropped below the boiler's safe operating threshold, typically below 0.5 bar. The boiler locks out to prevent running without adequate water circulation. Often it resolves with a repressurise and reset.

What does the f75 fault code mean on a Vaillant boiler?

F75 means the boiler's pressure sensor has not detected the expected change in water pressure when the pump starts. Vaillant lists low system pressure, air in the boiler or heating system, a faulty pressure sensor and a faulty pump as causes, and system sludge restricting flow can also play a part.

Can I reset an f22 fault myself?

Yes, if the cause is low system pressure. Check the pressure gauge, repressurise to between 1 and 1.5 bar using the filling loop, and press the reset button. If the F22 clears and the pressure holds for 24 hours, the fault is resolved. If the pressure drops again, there is an underlying leak or component fault that needs a Gas Safe engineer.

Can I reset an f75 fault myself?

You can attempt a reset, and in some cases it will clear a transient fault caused by air in the pump or a momentary sensor glitch. If F75 returns with the pressure between 1 and 1.5 bar, the fault is most likely in the pump or pressure sensor and needs professional diagnosis.

Why does my Vaillant boiler keep showing f22?

Recurring F22 faults after repressurising mean water is leaving the system somewhere. The most common causes are a slow leak at a radiator valve or pipe joint, a faulty pressure relief valve releasing water, or a failed expansion vessel.

How do I repressurise a Vaillant boiler?

Turn the boiler off. Locate the filling loop, usually beneath the boiler; some models have a filling key or a built-in filling device instead, so check your boiler's manual. Open the valve slowly and watch the gauge rise to between 1 and 1.5 bar. Close the valve, then press the reset button to restart the boiler.

Is f75 expensive to repair on a Vaillant boiler?

It depends on the diagnosis. A pressure sensor is an inexpensive part to replace. A pump costs more. If the cause is system sludge, a powerflush addresses the root problem but is a more involved job. A Gas Safe engineer can confirm the cause and provide a fixed quote before starting work.

Boiler losing pressure and you are in London or the South East?

FS Group's Gas Safe registered engineers carry out boiler pressure diagnostics and repairs across London and the South East, and aim to reach emergencies within two hours, subject to availability.